Application
Making use of wind power to generate electric power and
consequently charge the storage battery, then supply thestorage electric energy
to lighting, household appliances, communication equipments and motor tools in
the modeof DC or AC
Technical
Specification
1.Drive permanent magnet generator directly; the
generator adopts ferromagnetic material, with 2 times of
overload capability.
2.Starting with breeze, generating with class 2 wind,
good running with low wind velocity.
3.Excellent aerofoil design, in the wind tunnel test,
it shows high efficiency and low noise. The blades are madeaccording to the
structure and crafts of air propeller. Firm and durable, service life as long as
15-20 years.
4.The wind wheel and motor adopt universal connection,
run stably without vibration.
5.Closed power transmission slip ring, the cable will
not enwind.
6.Simple and strengthened design, enables it free from
special maintenance.
7.When meeting strong wind, there will be crosswind and
electromagnetic speed-limiting protection.
8.Direct current charging under constant voltage.
9.Lever type independent tower, convenient
installation, rising and falling.
10.Strict corrosion proof measures, anti atmosphere, fume or sand.
Mainly made up of wind wheel, generator, tail
vane, rack, cable, charging controller, inverter and storagebattery,etc.
|
Model |
WT |
WT |
WT |
WT |
WT |
WT |
WT |
WT |
WT |
WT |
WT |
|
-200 |
-300 |
-500 |
-1000 |
-2000 |
-3500 |
-5000 |
-7500 |
-10K |
-15K |
-20K |
|
Diameter of wind wheel
(m) |
2.2 |
2.5 |
2.8 |
3.2 |
4 |
5 |
6 |
7 |
8 |
10 |
12 |
|
Blade material |
Glass fibre reinforced
plastic*3 |
|
Rated wind speed (m/s) |
8 |
8 |
8 |
8 |
10 |
10 |
10 |
10 |
10 |
10 |
10 |
|
Starting wind speed
(m/s) |
3 |
|
Wind speed during
working (m/s) |
3-25 |
4-30 |
|
Safe wind speed (m/s) |
40 |
50 |
|
Rated power (W) |
200 |
300 |
500 |
1000 |
2000 |
3500 |
5000 |
7500 |
10000 |
15000 |
20000 |
|
Max power (W) |
300 |
500 |
800 |
1500 |
3000 |
4500 |
6500 |
9000 |
15000 |
21000 |
30000 |
|
Rated rotating speed
(r/min) |
450 |
420 |
400 |
360 |
280 |
220 |
190 |
160 |
120 |
100 |
95 |
|
Generator form |
Permanent magnet
generator, three-phase, AC |
|
Speed-limiting mode |
Lateral misalignment
and electromagnetic braking |
|
Working voltage (V) |
DC24/36V AC220V |
DC48/240V AC220V |
DC240V/500V AC220/380V |
DC500V AC380V |
|
Tower height (m) |
5.5 |
6 |
6 |
7 |
8 |
8 |
10 |
10/12 |
10/15 |
10/15 |
10/15 |
|
Weight (not include
tower) kg |
67 |
80 |
90 |
120 |
220 |
300 |
600 |
665 |
800 |
1300 |
1600 |
|
Weight of A/AA steel
pipe zipper (kg) |
40 |
65 |
85 |
100 |
160 |
150 |
800 |
800(10m) |
1000(12m) |
1500(15m) |
1650(15m) |
|
Weight of independent
mast (kg) |
230 |
250 |
280 |
350 |
380 |
450 |
1300 |
1300(10m) |
1800(10m) |
2800(15m) |
2800(15m) |
|
A/AA volume (CBM) |
0.5 |
0.5 |
0.5 |
0.6 |
1 |
0.7 |
4.4 |
4.5 |
5.2 |
6.5 |
6.5 |
|
AAA volume (CBM) |
0.5 |
0.5 |
0.7 |
0.8 |
1.3 |
1.3 |
6.2 |
6.3 |
7.4 |
8.5 |
9.6 |
|
AA--special corrosion
proof, steel pipe zipper type mast; AAA--special corrosion proof,
independent mast of manganese steel material, more convenient installation,
elegant, small floor space required |
|